Each file below is presented in both PDF and
Data Exchange Format (.dxf) format.
Simply click the PDF or DXF icons to begin downloading.
 |
Built-in roller shutter
box – flush with masonry |
(1.3.06) |
  |
Built-in
roller shutter box – projecting |
(1.3.07) |
  |
Cantilevered balcony
slab – insulated on all sides, ETICS – with starter track |
(1.6.01) |
  |
Cantilevered
balcony slab – insulated on all sides, ETICS directly applied |
(1.6.02) |
  |
Cantilevered balcony
slab – with thermal break |
(1.6.03) |
  |
Ceramic system |
(1.1.04) |
  |
Cylindrical plug as anchorage base for medium loads |
(1.7.03) |
  |
Cylindrical plug as pressure pad for anchorage of heavy loads |
(1.7.05) |
  |
DIFFUTHERM applied to panel product, with starter track at plinth |
(2.2.05) |
  |
Eaves / roof boarding junction (unventilated roof) |
(1.4.01) |
  |
Eaves / roof boarding junction (ventilated cold roof) |
(1.4.02) |
  |
Eaves / roof boarding junction (ventilated warm roof) |
(1.4.03) |
  |
Eaves / roof boarding junction for over-rafter insulation (ventilated roof) |
(1.4.04) |
  |
Eaves / roof boarding junction with DIFFUTHERM (unventilated roof) |
(2.4.01) |
  |
Eaves / roof boarding junction with THD N+F (unventilated roof) |
(2.4.01a) |
  |
ETICS applied to panel product, bottom junction with aluminium window sill, windows externally flush |
(2.3.09) |
  |
ETICS applied to panel product, bottom junction with aluminium window sill, windows internally flush |
(2.3.08) |
  |
ETICS applied to panel product, windows externally flush |
(2.3.02) |
  |
ETICS applied to panel product, windows internally flush |
(2.3.01) |
  |
Existing building |
(1.1.02) |
  |
Expansion joint (surface) with two stop beads |
(1.5.02) |
  |
Expansion joint (surface) with U-shaped section |
(1.5.01) |
  |
FID 50 anchor for later fixing of light loads to insulation |
(1.7.02) |
  |
Fixing rose for anchorage of light loads |
(1.7.01) |
  |
Flat roof junction (example with existing building) |
(1.4.08) |
  |
Flat roof junction (new-build example) |
(1.4.09) |
  |
Flush plinth junction |
(1.2.05) |
  |
Imitation ashlar render with trapezoidal fillet |
(1.9.04) |
  |
Incorporating jamb insulation |
(1.3.01) |
  |
Incorporating jamb insulation |
(1.3.02) |
  |
Incorporation of expansion joint in area of external fire spread |
(1.8.06) |
  |
Junction with existing works |
(1.5.04) |
  |
Junction with facing masonry using Quix |
(1.5.05) |
  |
Junction with guide rail for built-in roller shutter box |
(1.3.12) |
  |
Junction with guide rail for front-fixed roller shutter box |
(1.3.11) |
  |
Junction with ventilated curtain wall |
(1.5.06) |
  |
Lintel
construction incorporating LICHTKEIL as fire barrier |
(1.8.05) |
  |
Lintel construction incorporating mineral-fibre plank |
(1.8.01) |
  |
Lintel construction with front-fixed roller shutter box |
(1.8.03) |
  |
Lintel construction with scrim fold |
(1.8.02) |
  |
Lintel construction with volamit for windows proud of structural wall |
(1.8.04) |
  |
Monopitch roof / upper wall junction |
(1.4.06) |
  |
Monopitch roof / upper wall junction with stop bead for flashings |
(1.4.07) |
  |
New-build scheme |
(1.1.01) |
  |
Partial-area insulation – junction
with non-insulated area |
(1.9.01) |
  |
Partial-area insulation without thermal bridging at external building angle |
(1.9.02) |
  |
Pelmet over blind box |
(1.3.09) |
  |
Penthouse insulated on all sides |
(1.4.10) |
  |
Pitched roof / upper wall junction |
(1.4.05) |
  |
Pitched roof / upper wall junction with stop bead for flashings |
(1.4.05a) |
  |
Plinth insulation carried below ground with Quix |
(1.2.04) |
  |
Plinth insulation carried slightly below ground |
(1.2.08) |
  |
Plinth insulation not carried below ground |
(1.2.06) |
  |
Radiused Quix starter blocks at plinth |
(1.2.03) |
  |
Recess in facade with drip |
(1.9.03) |
  |
Roof edge junction |
(1.4.12) |
  |
Sliding joint (horizontal expansion joint) |
(1.5.03) |
  |
Solid timber construction directly faced with DIFFUTHERM / corner detailing |
(2.1.09) |
  |
Solid timber construction directly faced with DIFFUTHERM in areas subject to splashing |
(2.2.07) |
  |
Solid timber construction directly faced with DIFFUTHERM, fastener-fixed |
(2.1.08) |
  |
Solid timber construction directly faced with DIFFUTHERM, stapled |
(2.1.08a) |
  |
Solid timber construction directly faced with DIFFUTHERM, with starter track at plinth |
(2.2.06) |
  |
Solid timber construction double-faced with DIFFUTHERM, fastener-fixed |
(2.1.08b) |
  |
Solid timber construction double-faced with DIFFUTHERM, fastener-fixed |
(2.3.05) |
  |
Square-Edge Quix starter blocks at plinth |
(1.2.02) |
  |
Starter track at plinth |
(1.2.01) |
  |
Threshold with bracket supports (front balcony) |
(1.6.05) |
  |
Threshold with bracket supports (patio door) |
(1.6.06) |
  |
Timber studwork directly faced with DIFFUTHERM |
(2.1.02) |
  |
Timber studwork directly faced with DIFFUTHERM |
(2.1.03) |
  |
Timber studwork directly faced with DIFFUTHERM |
(2.1.04) |
  |
Timber studwork directly faced with DIFFUTHERM |
(2.1.05) |
  |
Timber studwork directly faced with DIFFUTHERM |
(2.1.06) |
  |
Timber studwork directly faced with DIFFUTHERM in areas subject to splashing |
(2.2.04) |
  |
Timber studwork directly faced with DIFFUTHERM, bottom junction with aluminium window sill, windows externally flush |
(2.3.11) |
  |
Timber studwork directly faced with DIFFUTHERM, bottom junction with aluminium window sill, windows internally flush |
(2.3.10) |
  |
Timber studwork directly faced with DIFFUTHERM, front-fixed roller shutter box, with starter track, timber / aluminium window |
(2.3.06) |
  |
Timber studwork directly faced with DIFFUTHERM, front-fixed roller shutter box, with starter track, timber window |
(2.3.07) |
  |
Timber studwork directly faced with DIFFUTHERM, plinth flush |
(2.2.03) |
  |
Timber studwork directly faced with DIFFUTHERM, windows externally flush |
(2.3.04) |
  |
Timber studwork directly faced with DIFFUTHERM, windows internally flush |
(2.3.03) |
  |
Timber studwork directly faced with DIFFUTHERM, with Quix starter blocks at plinth |
(2.2.08) |
  |
Timber studwork directly faced with DIFFUTHERM, with starter track at plinth |
(2.2.02) |
  |
Timber studwork directly faced with THD N+F |
(2.1.03a) |
  |
Timber studwork directly faced with THD N+F |
(2.1.04a) |
  |
Timber studwork directly faced with THD N+F in areas subject to splashing |
(2.2.04a) |
  |
Timber studwork directly faced with THD N+F, bottom junction with aluminium window sill, windows externally flush |
(2.3.11a) |
  |
Timber studwork directly faced with THD N+F, bottom junction with aluminium window sill, windows internally flush |
(2.3.10a) |
  |
Timber studwork directly faced with THD N+F, front-fixed roller shutter box, with starter track, timber / aluminium window |
(2.3.06a) |
  |
Timber studwork directly faced with THD N+F, front-fixed roller shutter box, with starter track, timber window |
(2.3.07a) |
  |
Timber studwork directly faced with THD N+F, plinth flush |
(2.2.03a) |
  |
Timber studwork directly faced with THD N+F, windows externally flush |
(2.3.04a) |
  |
Timber studwork directly faced with THD N+F, windows internally flush |
(2.3.03a) |
  |
Timber studwork directly faced with THD N+F, with Quix starter blocks at plinth |
(2.2.08a) |
  |
Timber studwork directly faced with THD N+F, with starter track at plinth |
(2.2.02a) |
  |
Timber
studwork directly faced with THD N+F |
(2.1.02a) |
  |
Timber studwork with ETICS applied to panel product |
(2.1.01) |
  |
Timber studwork with ETICS applied to panel product, with starter track at plinth |
(2.2.01) |
  |
Top junction with front-fixed roller shutter box |
(1.3.08) |
  |
Track system |
(1.1.03) |
  |
Universal mounting plate for anchorage of heavy loads |
(1.7.06) |
  |
Widening of roof edge with edge trim |
(1.4.11) |
  |
Window apron unit, window proud of structural wall |
(1.3.10) |
  |
Window flush with structural wall, with waterproof sheet |
(1.3.05) |
  |
Window flush, bottom junction with aluminium window sill |
(1.3.04) |
  |
Window recessed, bottom junction with aluminium window sill |
(1.3.03) |
  |
Zyrillo as anchorage base for medium loads |
(1.7.04) |